PRODUCT CATEGORY
Hospital vacuum center suction system
2BV/VC/VLR/VTN/MW/MV/MC
*Water type series: using water ring vacuum pump, equipped with steam-water separator, water recycling, economical and reliable, widely used, ultimate vacuum 33mbar (abs), rated flow 27 ~ 2260m3/h. *Oil type series: oil type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), rated flow 50-2200m3/h. . *Dry claw pump series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), rated flow 60 ~ 1900m3/h.
Classification:
Key words:
- Product description
- parameter
-
- Commodity name: Hospital vacuum center suction system
- Commodity ID: 2BV/VC/VLR/VTN/MW/MV/MC
*Water type series: using water ring vacuum pump, equipped with steam-water separator, water recycling, economical and reliable, widely used, ultimate vacuum 33mbar (abs), rated flow 27 ~ 2260m3/h. *Oil type series: oil type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), rated flow 50-2200m3/h. . *Dry claw pump series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), rated flow 60 ~ 1900m3/h.
Medical vacuum pump negative pressure central suction system
details:
Product Brand:Rietschle
Product model: VC303 Body material: alloy Drive mode: electric Process use: vacuum Working principle: oil type rotary vane Motor Power:7.5kW
Ultimate pressure:50Pa
Dimensions:
Product number:
MW series: use NASH 2BV2 060/061/070/071, 2BV5 110/111/121/131/161 and 2BE1 202/203 water circulation vacuum pumps
MV series: use Liqile VC50/75/100/150/202/303/400/500/700/900/1100/1300 oil type optional vacuum pump
MC series: use Liqile VLR60/100/150/250/251/300/400/500/1000 dry claw vacuum pump
MG series: use Liqile VTN10, VTN15, VTN25, VTN40 dry rotary vane vacuum pumpProvide international brand medical vacuum pumps, vacuum negative pressure center suction system, professional design, production, installation, first-class quality.
Working principle (take MW series as an example):

Ledun has provided medical center attraction stations for hospitals and medical engineering companies for nearly ten years. Adhering to the design concept of human-oriented science and technology and product excellence, after years of technical accumulation, technological improvement and technological innovation, the products we provide have Three major product advantages of systemization, intelligence, safety and reliability.
Systematization:It can provide owners with optimized vacuum pumps, buffer tanks, sewage tanks, sub-cylinders, pipelines, instruments, valves, electrical control cabinets, bacterial filters, pre- and post-filters and other medical central suction station system complete sets of equipment, and also It can provide a complete set of engineering services from product selection, design, manufacturing, to installation, commissioning, and acceptance.
Intelligent:It can provide PLC control module and HMI man-machine interface operation. You can choose to automatically increase or decrease the vacuum pump and alternate operation, reminders for regular replacement of consumables, sound and light alarm for negative pressure exceeding limit, motor operation monitoring, system temperature exceeding alarm, system positive pressure alarm and Intelligent modules such as emergency stop and remote system data transmission make management and operation easier and clearer.
Safe and reliable:In the selection of vacuum pumps, we only use top-notch imported vacuum pumps or high-quality domestic brand-name vacuum pumps to ensure that their design service life reaches more than ten years and meet the strict requirements of hospitals for high reliability of medical equipment; in terms of supporting equipment, Sewage discharge, bacterial filtration, pre- and post-filtration, system monitoring, alarm, emergency stop, remote data transmission and other modules meet the requirements of clean emissions and also ensure that the medical center system can operate safely for a long time.
Features:
*MW series adopts water ring vacuum pump, equipped with steam-water separator, water cycle use, economical and reliable, wide application, ultimate vacuum 33mbar (abs), flow 27-2260m3/h.
*MV series: oil-type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), flow 50-2200m3/h.
*MC series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), flow rate 60 ~ 1900m3/h.
*MG series: It adopts dry rotary vane vacuum pump, dry operation, suitable for anesthesia or breathing exhaust gas discharge, single pump air volume 11.7~42m3/h.
typical application:
The MW, MV, and MC series are professionally used for vacuum suction in medical, medical and hospitals, and the MG series are suitable for anesthesia or exhaust gas discharge.

Selection and ordering information:
NASH MW series selection and ordering information:50Hz,380V,3AC,IP55, F
Attraction station model Rated
flowm3/h
limit
pressurembar.A
Continuous operating pressure
mbar.A
Vacuum pump
modelNumber of vacuum pumps Attraction station control method Inlet/exhaust port diameter
DN
Vacuum pump speed
r/min
Total power
kW
Average noise
dB(A)
MW060-2
27
33
>80
2BV2060
1+1
Panel
25
2850
1.62
62
MW061-2
52
33
>80
2BV2061
1+1
Panel
25
2850
2.9
65
MW070-2
80
33
>80
2BV2070
1+1
Panel
40
2850
4.7
66
MW071-2
110
33
>80
2BV2071
1+1
Panel
40
2850
7.7
72
MW110-2
165
33
>80
2BV5110
1+1
Panel
50
1450
8.0
63
MW111-2
230
33
>80
2BV5111
1+1
Panel
50
1450
11
68
MW121-2
280
33
>80
2BV5121
1+1
Panel
65
1450
15
69
MW131-2
400
33
>80
2BV5131
1+1
Panel
65
1450
22
73
MW161-2
500
33
>80
2BV5161
1+1
Panel
80
980
30
74
MW202-2
760
33
>80
2BE1202
1+1
Panel
100
980
44
-
MW203-2
1130
33
>80
2BE1203
1+1
Panel
100
980
74
-
MW110-3
330
33
>80
2BV5110
2+1
PLC+HMI
80
1450
8.0
63
MW111-3
460
33
>80
2BV5111
2+1
PLC+HMI
80
1450
11
68
MW121-3
560
33
>80
2BV5121
2+1
PLC+HMI
80
1450
15
69
MW131-3
800
33
>80
2BV5131
2+1
PLC+HMI
80
1450
22
73
MW161-3
1000
33
>80
2BV5161
2+1
PLC+HMI
100
980
45
74
MW202-3
1520
33
>80
2BE1202
2+1
PLC+HMI
125
980
66
-
MW203-3
2260
33
>80
2BE1203
2+1
PLC+HMI
150
980
111
-
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MV series selection and ordering information:50Hz,380V,3AC,IP55, F
Attraction station model Rated
flowm3/h
limit
pressurembar.A
Continuous operating pressure
mbar.A
Vacuum pump
modelNumber of vacuum pumps Attraction station control method Inlet/exhaust port diameter
DN
Vacuum pump speed
r/min
Total power
kW
Average noise
dB(A)
MV50-2
50
0.1
>0.5
VC50
1+1
Panel
40
1450
3.0
64
MV75-2
70
0.1
>0.5
VC75
1+1
Panel
40
1450
4.4
64
MV100-2
100
0.1
>0.5
VC100
1+1
Panel
40
1450
6.0
66
MV150-2
150
0.1
>0.5
VC150
1+1
Panel
40
1450
8.0
68
MV202-2
200
0.1
>0.5
VC202
1+1
Panel
50
1450
11
69
MV303-2
300
0.1
>0.5
VC303
1+1
Panel
50
1450
15
70
MV400-2
400
0.1
>0.5
VC400
1+1
Panel
80
950
22
73
MV500-2
550
0.1
>0.5
VC500
1+1
Panel
80
950
30
75
MV700-2
700
0.1
>0.5
VC700
1+1
Panel
80
950
37
78
MV900-2
830
0.1
>0.5
VC900
1+1
Panel
100
950
44
79
MV1100-2
1100
0.1
>0.5
VC1100
1+1
Panel
100
950
60
83
MV202-3
400
0.1
>0.5
VC202
2+1
PLC+HMI
80
1450
16.5
69
MV303-3
600
0.1
>0.5
VC303
2+1
PLC+HMI
80
1450
22.5
70
MV400-3
800
0.1
>0.5
VC400
2+1
PLC+HMI
100
950
33
73
MV500-3
1100
0.1
>0.5
VC500
2+1
PLC+HMI
100
950
45
75
MV700-3
1400
0.1
>0.5
VC700
2+1
PLC+HMI
125
950
55.5
78
MV900-3
1660
0.1
>0.5
VC900
2+1
PLC+HMI
125
950
66
79
MV1100-3
2200
0.1
>0.5
VC1100
2+1
PLC+HMI
150
950
90
83
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MC series selection and ordering information::50Hz,380V,3AC,IP55, F
Attraction station model Rated
flowm3/h
limit
pressurembar.A
Continuous operating pressure
mbar.A
Vacuum pump
modelNumber of vacuum pumps Attraction station control method Inlet/exhaust port diameter
DN
Vacuum pump speed
r/min
Total power
kW
Average noise
dB(A)
MC60-2
60
50
>100
VLR60
1+1
Panel
25
2850
2.2
78
MC100-2
100
50
>150
VLR100
1+1
Panel
40
2850
4.4
78
MC150-2
150
50
>100
VLR150
1+1
Panel
40
2850
6.0
79
MC251-2
211
50
>200
VLR251
1+1
Panel
50
2850
8.0
78
MC250-2
235
50
>200
VLR250
1+1
Panel
50
2850
8.0
78
MC300-2
300
50
>200
VLR300
1+1
Panel
50
2850
11
79
MC400-2
385
50
>250
VLR400
1+1
Panel
80
2850
15
82
MC500-2
500
50
>250
VLR500
1+1
Panel
80
2850
18
82
MC1000-2
950
50
>200
VLR1000
1+1
Panel
100
2850
37
82
MC150-3
300
50
>100
VLR251
2+1
PLC+HMI
50
2850
9.0
79
MC251-3
422
50
>200
VLR251
2+1
PLC+HMI
80
2850
12
78
MC250-3
470
50
>200
VLR250
2+1
PLC+HMI
80
2850
12
78
MC300-3
600
50
>200
VLR300
2+1
PLC+HMI
80
2850
16.5
79
MC400-3
770
50
>250
VLR400
2+1
PLC+HMI
100
2850
22.5
82
MC500-3
1000
50
>250
VLR500
2+1
PLC+HMI
100
2850
27
82
MC1000-3
1900
50
>200
VLR1000
2+1
PLC+HMI
150
2850
55.5
82
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MG series selection and ordering information::50Hz,380V,3AC,IP55, F
Attraction station model Number of operating rooms Rated
flowm3/h
limit
pressurembar.A
Continuous operating pressure
mbar.A
Vacuum pump
modelNumber of vacuum pumps Attraction station control method Inlet/exhaust port diameter
DN
Vacuum pump speed
r/min
Total power
kW
Average noise
dB(A)
MG10-2
≤3
11.7
150
850
VTN10
1+1
PLC+HMI
40
1450
0.74
60
MG15-2
3~7
17.0
150
>150
VTN15
1+1
PLC+HMI
40
1450
1.1
61
MG25-2
7~10
25.8
150
>150
VTN25
1+1
PLC+HMI
40
1450
1.5
64
MG40-2
10~20
42.0
150
850
VTN40
1+1
PLC+HMI
40
1450
3.0
67
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Detailed information such as product performance curve:
Please call, fax, email or contact our sales engineer via QQ, we will serve you wholeheartedly.
TEL: 020-39987161 E-Mail: lidunjixie@163.com QQ:121450481
-
-
Main parameters of vacuum pump
- Product model:
- Maximum flow rate:
- Limiting vacuum:
- Motor type:
- Power:
- Average noise:
- Average weight:
-
Online Inquiry