Papua New Guinea Hospital vacuum center suction system
Category:
Papua New GuineaVacuum system engineering
Product Description
Medical vacuum pump negative pressure central suction system
details:
|
Product Brand:Rietschle |
Product model: VC303 | Body material: alloy |
| Drive mode: electric | Process use: vacuum | Working principle: oil type rotary vane |
|
Motor Power:7.5kW |
Ultimate pressure:50Pa |
Dimensions: |
Product number:
MW series: use NASH 2BV2 060/061/070/071, 2BV5 110/111/121/131/161 and 2BE1 202/203 water circulation vacuum pumps
MV series: use Liqile VC50/75/100/150/202/303/400/500/700/900/1100/1300 oil type optional vacuum pump
MC series: use Liqile VLR60/100/150/250/251/300/400/500/1000 dry claw vacuum pump
MG series: use Liqile VTN10, VTN15, VTN25, VTN40 dry rotary vane vacuum pump
Provide international brand medical vacuum pumps, vacuum negative pressure center suction system, professional design, production, installation, first-class quality.
Working principle (take MW series as an example):
Ledun has provided medical center attraction stations for hospitals and medical engineering companies for nearly ten years. Adhering to the design concept of human-oriented science and technology and product excellence, after years of technical accumulation, technological improvement and technological innovation, the products we provide have Three major product advantages of systemization, intelligence, safety and reliability.
Systematization:It can provide owners with optimized vacuum pumps, buffer tanks, sewage tanks, sub-cylinders, pipelines, instruments, valves, electrical control cabinets, bacterial filters, pre- and post-filters and other medical central suction station system complete sets of equipment, and also It can provide a complete set of engineering services from product selection, design, manufacturing, to installation, commissioning, and acceptance.
Intelligent:It can provide PLC control module and HMI man-machine interface operation. You can choose to automatically increase or decrease the vacuum pump and alternate operation, reminders for regular replacement of consumables, sound and light alarm for negative pressure exceeding limit, motor operation monitoring, system temperature exceeding alarm, system positive pressure alarm and Intelligent modules such as emergency stop and remote system data transmission make management and operation easier and clearer.
Safe and reliable:In the selection of vacuum pumps, we only use top-notch imported vacuum pumps or high-quality domestic brand-name vacuum pumps to ensure that their design service life reaches more than ten years and meet the strict requirements of hospitals for high reliability of medical equipment; in terms of supporting equipment, Sewage discharge, bacterial filtration, pre- and post-filtration, system monitoring, alarm, emergency stop, remote data transmission and other modules meet the requirements of clean emissions and also ensure that the medical center system can operate safely for a long time.
Features:
*MW series adopts water ring vacuum pump, equipped with steam-water separator, water cycle use, economical and reliable, wide application, ultimate vacuum 33mbar (abs), flow 27-2260m3/h.
*MV series: oil-type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), flow 50-2200m3/h.
*MC series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), flow rate 60 ~ 1900m3/h.
*MG series: It adopts dry rotary vane vacuum pump, dry operation, suitable for anesthesia or breathing exhaust gas discharge, single pump air volume 11.7~42m3/h.
typical application:
The MW, MV, and MC series are professionally used for vacuum suction in medical, medical and hospitals, and the MG series are suitable for anesthesia or exhaust gas discharge.

Selection and ordering information:
NASH MW series selection and ordering information:50Hz,380V,3AC,IP55, F
| Attraction station model |
Rated m3/h |
limit mbar.A |
Continuous operating pressure mbar.A |
Vacuum pump model |
Number of vacuum pumps | Attraction station control method |
Inlet/exhaust port diameter DN |
Vacuum pump speed r/min |
Total power kW |
Average noise dB(A) |
|
MW060-2 |
27 |
33 |
>80 |
2BV2060 |
1+1 |
Panel |
25 |
2850 |
1.62 |
62 |
|
MW061-2 |
52 |
33 |
>80 |
2BV2061 |
1+1 |
Panel |
25 |
2850 |
2.9 |
65 |
|
MW070-2 |
80 |
33 |
>80 |
2BV2070 |
1+1 |
Panel |
40 |
2850 |
4.7 |
66 |
|
MW071-2 |
110 |
33 |
>80 |
2BV2071 |
1+1 |
Panel |
40 |
2850 |
7.7 |
72 |
|
MW110-2 |
165 |
33 |
>80 |
2BV5110 |
1+1 |
Panel |
50 |
1450 |
8.0 |
63 |
|
MW111-2 |
230 |
33 |
>80 |
2BV5111 |
1+1 |
Panel |
50 |
1450 |
11 |
68 |
|
MW121-2 |
280 |
33 |
>80 |
2BV5121 |
1+1 |
Panel |
65 |
1450 |
15 |
69 |
|
MW131-2 |
400 |
33 |
>80 |
2BV5131 |
1+1 |
Panel |
65 |
1450 |
22 |
73 |
|
MW161-2 |
500 |
33 |
>80 |
2BV5161 |
1+1 |
Panel |
80 |
980 |
30 |
74 |
|
MW202-2 |
760 |
33 |
>80 |
2BE1202 |
1+1 |
Panel |
100 |
980 |
44 |
- |
|
MW203-2 |
1130 |
33 |
>80 |
2BE1203 |
1+1 |
Panel |
100 |
980 |
74 |
- |
|
MW110-3 |
330 |
33 |
>80 |
2BV5110 |
2+1 |
PLC+HMI |
80 |
1450 |
8.0 |
63 |
|
MW111-3 |
460 |
33 |
>80 |
2BV5111 |
2+1 |
PLC+HMI |
80 |
1450 |
11 |
68 |
|
MW121-3 |
560 |
33 |
>80 |
2BV5121 |
2+1 |
PLC+HMI |
80 |
1450 |
15 |
69 |
|
MW131-3 |
800 |
33 |
>80 |
2BV5131 |
2+1 |
PLC+HMI |
80 |
1450 |
22 |
73 |
|
MW161-3 |
1000 |
33 |
>80 |
2BV5161 |
2+1 |
PLC+HMI |
100 |
980 |
45 |
74 |
|
MW202-3 |
1520 |
33 |
>80 |
2BE1202 |
2+1 |
PLC+HMI |
125 |
980 |
66 |
- |
|
MW203-3 |
2260 |
33 |
>80 |
2BE1203 |
2+1 |
PLC+HMI |
150 |
980 |
111 |
- |
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MV series selection and ordering information:50Hz,380V,3AC,IP55, F
| Attraction station model |
Rated m3/h |
limit mbar.A |
Continuous operating pressure mbar.A |
Vacuum pump model |
Number of vacuum pumps | Attraction station control method |
Inlet/exhaust port diameter DN |
Vacuum pump speed r/min |
Total power kW |
Average noise dB(A) |
|
MV50-2 |
50 |
0.1 |
>0.5 |
VC50 |
1+1 |
Panel |
40 |
1450 |
3.0 |
64 |
|
MV75-2 |
70 |
0.1 |
>0.5 |
VC75 |
1+1 |
Panel |
40 |
1450 |
4.4 |
64 |
|
MV100-2 |
100 |
0.1 |
>0.5 |
VC100 |
1+1 |
Panel |
40 |
1450 |
6.0 |
66 |
|
MV150-2 |
150 |
0.1 |
>0.5 |
VC150 |
1+1 |
Panel |
40 |
1450 |
8.0 |
68 |
|
MV202-2 |
200 |
0.1 |
>0.5 |
VC202 |
1+1 |
Panel |
50 |
1450 |
11 |
69 |
|
MV303-2 |
300 |
0.1 |
>0.5 |
VC303 |
1+1 |
Panel |
50 |
1450 |
15 |
70 |
|
MV400-2 |
400 |
0.1 |
>0.5 |
VC400 |
1+1 |
Panel |
80 |
950 |
22 |
73 |
|
MV500-2 |
550 |
0.1 |
>0.5 |
VC500 |
1+1 |
Panel |
80 |
950 |
30 |
75 |
|
MV700-2 |
700 |
0.1 |
>0.5 |
VC700 |
1+1 |
Panel |
80 |
950 |
37 |
78 |
|
MV900-2 |
830 |
0.1 |
>0.5 |
VC900 |
1+1 |
Panel |
100 |
950 |
44 |
79 |
|
MV1100-2 |
1100 |
0.1 |
>0.5 |
VC1100 |
1+1 |
Panel |
100 |
950 |
60 |
83 |
|
MV202-3 |
400 |
0.1 |
>0.5 |
VC202 |
2+1 |
PLC+HMI |
80 |
1450 |
16.5 |
69 |
|
MV303-3 |
600 |
0.1 |
>0.5 |
VC303 |
2+1 |
PLC+HMI |
80 |
1450 |
22.5 |
70 |
|
MV400-3 |
800 |
0.1 |
>0.5 |
VC400 |
2+1 |
PLC+HMI |
100 |
950 |
33 |
73 |
|
MV500-3 |
1100 |
0.1 |
>0.5 |
VC500 |
2+1 |
PLC+HMI |
100 |
950 |
45 |
75 |
|
MV700-3 |
1400 |
0.1 |
>0.5 |
VC700 |
2+1 |
PLC+HMI |
125 |
950 |
55.5 |
78 |
|
MV900-3 |
1660 |
0.1 |
>0.5 |
VC900 |
2+1 |
PLC+HMI |
125 |
950 |
66 |
79 |
|
MV1100-3 |
2200 |
0.1 |
>0.5 |
VC1100 |
2+1 |
PLC+HMI |
150 |
950 |
90 |
83 |
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MC series selection and ordering information::50Hz,380V,3AC,IP55, F
| Attraction station model |
Rated m3/h |
limit mbar.A |
Continuous operating pressure mbar.A |
Vacuum pump model |
Number of vacuum pumps | Attraction station control method |
Inlet/exhaust port diameter DN |
Vacuum pump speed r/min |
Total power kW |
Average noise dB(A) |
|
MC60-2 |
60 |
50 |
>100 |
VLR60 |
1+1 |
Panel |
25 |
2850 |
2.2 |
78 |
|
MC100-2 |
100 |
50 |
>150 |
VLR100 |
1+1 |
Panel |
40 |
2850 |
4.4 |
78 |
|
MC150-2 |
150 |
50 |
>100 |
VLR150 |
1+1 |
Panel |
40 |
2850 |
6.0 |
79 |
|
MC251-2 |
211 |
50 |
>200 |
VLR251 |
1+1 |
Panel |
50 |
2850 |
8.0 |
78 |
|
MC250-2 |
235 |
50 |
>200 |
VLR250 |
1+1 |
Panel |
50 |
2850 |
8.0 |
78 |
|
MC300-2 |
300 |
50 |
>200 |
VLR300 |
1+1 |
Panel |
50 |
2850 |
11 |
79 |
|
MC400-2 |
385 |
50 |
>250 |
VLR400 |
1+1 |
Panel |
80 |
2850 |
15 |
82 |
|
MC500-2 |
500 |
50 |
>250 |
VLR500 |
1+1 |
Panel |
80 |
2850 |
18 |
82 |
|
MC1000-2 |
950 |
50 |
>200 |
VLR1000 |
1+1 |
Panel |
100 |
2850 |
37 |
82 |
|
MC150-3 |
300 |
50 |
>100 |
VLR251 |
2+1 |
PLC+HMI |
50 |
2850 |
9.0 |
79 |
|
MC251-3 |
422 |
50 |
>200 |
VLR251 |
2+1 |
PLC+HMI |
80 |
2850 |
12 |
78 |
|
MC250-3 |
470 |
50 |
>200 |
VLR250 |
2+1 |
PLC+HMI |
80 |
2850 |
12 |
78 |
|
MC300-3 |
600 |
50 |
>200 |
VLR300 |
2+1 |
PLC+HMI |
80 |
2850 |
16.5 |
79 |
|
MC400-3 |
770 |
50 |
>250 |
VLR400 |
2+1 |
PLC+HMI |
100 |
2850 |
22.5 |
82 |
|
MC500-3 |
1000 |
50 |
>250 |
VLR500 |
2+1 |
PLC+HMI |
100 |
2850 |
27 |
82 |
|
MC1000-3 |
1900 |
50 |
>200 |
VLR1000 |
2+1 |
PLC+HMI |
150 |
2850 |
55.5 |
82 |
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Rietschle MG series selection and ordering information::50Hz,380V,3AC,IP55, F
| Attraction station model | Number of operating rooms |
Rated m3/h |
limit mbar.A |
Continuous operating pressure mbar.A |
Vacuum pump model |
Number of vacuum pumps | Attraction station control method |
Inlet/exhaust port diameter DN |
Vacuum pump speed r/min |
Total power kW |
Average noise dB(A) |
|
MG10-2 |
≤3 |
11.7 |
150 |
850 |
VTN10 |
1+1 |
PLC+HMI |
40 |
1450 |
0.74 |
60 |
|
MG15-2 |
3~7 |
17.0 |
150 |
>150 |
VTN15 |
1+1 |
PLC+HMI |
40 |
1450 |
1.1 |
61 |
|
MG25-2 |
7~10 |
25.8 |
150 |
>150 |
VTN25 |
1+1 |
PLC+HMI |
40 |
1450 |
1.5 |
64 |
|
MG40-2 |
10~20 |
42.0 |
150 |
850 |
VTN40 |
1+1 |
PLC+HMI |
40 |
1450 |
3.0 |
67 |
Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.
Detailed information such as product performance curve:
Please call, fax, email or contact our sales engineer via QQ, we will serve you wholeheartedly.
TEL: 020-39987161 E-Mail: lidunjixie@163.com QQ:121450481