Papua New Guinea Water ring roots vacuum unit

*Single roots series: single roots vacuum pump + water ring vacuum pump, anti-corrosion, explosion-proof structure can be selected, the pumping rate is 108~2160m3/h, and the ultimate vacuum is 400Pa. *Double Roots series: Double Roots vacuum pump + liquid ring vacuum pump, can choose anti-corrosion and explosion-proof structure, pumping rate 108~18000m3/h, ultimate vacuum 40Pa. *Three Roots series: Three Roots vacuum pump + liquid ring vacuum pump, can choose anti-corrosion, explosion-proof structure, pumping rate 108 ~ 36000m3/h, ultimate vacuum 1Pa.

Category:

Papua New GuineaRoots Vacuum Unit

Product Description

Roots water ring vacuum unit

details:

Product Brand: Lidun Product model: RLS Body material: alloy
Drive mode: electric Process use: vacuum Working principle: vacuum pump combination

Motor Power:3.75-250kW

Ultimate pressure:1~267Pa

Dimensions:

 

Product number:

Single Roots Series:RLS1082525401080162021603240360043206480900013500Suffix 1 digit

Double Roots Series:RLS1082525401080216036005400900018000Suffix 2 digit

Three Roots Series:RLS108252540108021603600540090001800036000Suffix 3 digit

Provide international brand, domestic brand vacuum pump unit, professional design, production, installation, can meet your general or special vacuum process。

 

 

Working principle (take three roots series as an example):

Roots vacuum pump is a positive displacement vacuum pump. It uses a pair of figure 8 rotors to rotate in the pump casing at constant speed and reverse rotation to produce suction/exhaust. Because there is a certain gap between the rotor and the pump casing and between the rotor and the rotor, a part of the gas will flow back through the gap and the suction port during the working process, which affects the ultimate vacuum of the pump.
The suction/exhaust process of the Roots vacuum pump will produce compression heat. When the heat is too large and cannot be dissipated in time, it will cause the rotor to overheat and expand and become stuck. Therefore, it is usually not used alone, and a fore vacuum pump must be configured. When a bypass relief valve is added to the roots vacuum pump, it can start working simultaneously with the foreline vacuum pump without overloading. When the Roots vacuum pump is designed with a gas circulation cooling circuit, the temperature of the vacuum pump rotor can be cooled by cooling gas, which can alleviate the phenomenon of rotor overheating expansion and jamming. This kind of pump becomes an air-cooled Roots vacuum pump.
It is recommended to use a liquid ring vacuum pump as the fore vacuum pump of the Luo vacuum pump. Single, double and three roots pumps with liquid ring pumps are available. When water is used as the working fluid of the liquid ring pump, the ultimate pressures of 267Pa, 27Pa, 1Pa can usually be obtained, and it is applied to the suction pressure range of 10~8000Pa (equivalent to -0.096~-0.101MPa.G).

  • When the liquid ring pump uses transformer oil, ethylene glycol, sulfuric acid, aniline, tetrachloroethylene, etc. as the working fluid, the ultimate pressure and application range of the unit are more extensive.
  • When the air-cooled Roots pump and liquid ring pump are combined, the suction pressure can be broadened to the range of 10 to 20000Pa (equivalent to -0.08 to -0.101MPa.G), and the energy saving effect is more prominent.
  • The roots liquid ring vacuum unit can make up for the disadvantage of the single liquid ring pump's low vacuum degree, and can also be used to remove flammable, explosive, and small amount of dust and liquid process gas.
  • If the liquid ring pump in the vacuum unit adopts the closed-loop operation mode, there is basically no waste liquid discharge during the working process of the unit, so it is cleaner and environmentally friendly.

 

Features:

Single Roots series: Single Roots vacuum pump + liquid ring vacuum pump, can choose anti-corrosion, explosion-proof structure, pumping rate 108 ~ 2160m3/h, ultimate vacuum 267Pa.

Double Roots series: Double Roots vacuum pump + liquid ring vacuum pump, can choose anti-corrosion, explosion-proof structure, pumping rate 108~18000m3/h, ultimate vacuum 27Pa.

Three-roots series: three-roots vacuum pump + liquid ring vacuum pump, can choose anti-corrosion, explosion-proof structure, pumping rate 108 ~ 36000m3/h, ultimate vacuum 1Pa.

 

typical application:

Vacuum distillation and crystallization in the chemical industry; vacuum concentration, drying and crystallization in the pharmaceutical industry; food freeze-drying and physical refining of edible oil; electronic circuit board pressing; vacuum degassing in the building materials industry; polyester chips in the textile industry; 10 to 20,000 Pa suction in various industries Vacuum process for pressure range.

 

Selection and ordering information: 

    

 Single Roots Liquid Ring Vacuum Unit Selection and Ordering Information:50Hz380V3ACIP54/55F

Unit Type

Pumping speed

m3/h

Selection of vacuum pump models of the unit

limit
pressure

Pa.A

Suggested work
Pressure range

Pa.A

Inhale

caliber

DN

exhaust

caliber

DN

total

power

kW

Main pump Foreline pump

RLS108-1

108

ZJ30

2BV2070

267

4000~8000

40

40

3.75

RLS108-2

108

ZJ30

2BV2061

267

2000~4000

25

25

2.25

RLS252-1

252

ZJ70

2BV5110

267

4000~8000

50

50

5.50

RLS252-2

252

ZJ70

2BV2071

267

2000~4000

40

40

5.50

RLS540-1

540

ZJ150

2BV5131

267

4000~8000

65

65

14.0

RLS540-2

540

ZJ150

2BV5121

267

2000~4000

65

65

10.5

RLS1080-1

1080

ZJ300

2BE1202

267

3000~8000

125

125

27.5

RLS1080-2

1080

ZJ300

2BV5161

267

2000~4000

80

80

20.5

RLS2160-1

2160

ZJ600

2BE1253

267

3000~6000

150

150

60.5

RLS3600-1

3600

ZJ1000

2BE1303

267

2000~6000

200

200

86.0

RLS1080-3

1080

ZJQ300

2BV5131

267

3000~20000

150

65

22.0

RLS1620-2

1620

ZJQ450

2BE1202

267

3000~25000

200

125

37.0

RLS2160-3

2160

ZJQ600

2BE1202

267

3000~20000

200

125

44.0

RLS3240-3

3240

ZJQ900

2BE1203

267

2000~22000

250

125

74.0

RLS4320-4

4320

ZJQ1200

2BE1203

267

1500~18000

250

125

92.0

RLS6480-4

6480

ZJQ1800

2BE1252

267

1500~16000

300

150

120.0

RLS9000-3

9000

ZJQ2500

2BE1303

267

1500~16000

400

200

150.0

RLS13500-4

13500

ZJQ3750

2BE1303

267

1500~10000

400

200

185.0

 

Double Roots Liquid Ring Vacuum Unit Selection and Ordering Information:50Hz380V3ACIP4455BF

Unit Type

Pumping speed

m3/h

Selection of vacuum pump models of the unit

limit
pressure

Pa.A

Suggested work
Pressure range

Pa.A

Inhale

caliber

DN

exhaust

caliber

DN

total

power

kW

Main pump Foreline pump

RLS108-21

108

ZJ30

ZJ152BV2061

27

400~6000

50

25

2.80

RLS252-21

252

ZJ70

ZJ352BV2070

27

400~6000

80

40

6.00

RLS540-21

540

ZJ150

ZJ752BV5111

27

400~5000

100

50

11.5

RLS1080-21

1080

ZJ300

ZJ1502BV5131

27

400~3000

150

65

18.0

RLS2160-21

2160

ZJ600

ZJ3002BE1202

27

400~3000

150

125

33.0

RLS2160-31

2160

ZJ600

ZJ2002BV5161

27

400~1500

150

80

24.5

RLS3600-31

3600

ZJ1000

ZJ3002BE1202

27

400~2000

200

125

38.5

RLS5400-23

5400

ZJ1500

ZJQ6002BE1202

27

400~1500

200

125

52.0

RLS9000-23

9000

ZJ2500

ZJQ12002BE1252

27

400~1500

300

150

97.0

RLS18000-23

18000

ZJ5000

ZJQ25002BE1303

27

400~1500

400

200

175.0

 

Three Roots Liquid Ring Vacuum Unit Selection and Ordering Information:50Hz380V3ACIP4455BF

Unit Type

Pumping speed

m3/h

Selection of vacuum pump models of the unit

limit
pressure

Pa.A

Suggested work
Pressure range

Pa.A

Inhale

caliber

DN

exhaust

caliber

DN

total

power

kW

Main pump Foreline pump

RLS108-221

108

ZJ30

ZJ15ZJ102BV2060

1

10~6000

50

25

2.95

RLS252-221

252

ZJ70

ZJ30ZJ152BV2061

1

10~3000

80

25

4.30

RLS540-221

540

ZJ150

ZJ70ZJ352BV2070

1

10~2000

100

40

9.00

RLS540-521

540

ZJ150

ZJ30ZJ152BV2061

1

10~1000

100

25

5.80

RLS1080-221

1080

ZJ300

ZJ150ZJ752BV5111

1

10~2000

150

50

15.5

RLS1080-421

1080

ZJ300

ZJ70ZJ352BV2070

1

10~1000

150

40

10.0

RLS2160-221

2160

ZJ600

ZJ300ZJ1502BV5131

1

10~2000

150

65

23.5

RLS2160-421

2160

ZJ600

ZJ150ZJ752BV5111

1

10~1000

150

50

17.0

RLS3600-321

3600

ZJ1000

ZJ300ZJ1502BV5131

1

10~1000

200

65

29.0

RLS5400-221

5400

ZJ1500

ZJ600ZJ3002BE1202

1

10~1000

200

125

44.0

RLS5400-521

5400

ZJ1500

ZJ300ZJ1502BV5131

1

10~800

200

65

33.0

RLS9000-223

9000

ZJ2500

ZJ1200ZJQ6002BE1202

1

10~800

300

125

77.0

RLS18000-223

18000

ZJ5000

ZJ2500ZJQ12002BE1252

1

10~800

400

150

142.0

RLS36000-223

36000

ZJ10000

ZJ5000ZJQ25002BE1303

1

10~800

500

200

250.0

Note: The recommended working pressure range in the table is based on the data under the conditions of air intake at 20°C, working water at 25°C, and exhaust pressure 101.3kPa.A, for reference for selection. 

  

Product performance curve and other details:

Please call, fax, email or contact our sales engineer via QQ, we will serve you wholeheartedly.

TEL: 020-39987161  E-Mail: lidunjixie@163.com   QQ:121450481