sao tome and principe Hospital vacuum center suction system

*Water type series: using water ring vacuum pump, equipped with steam-water separator, water recycling, economical and reliable, widely used, ultimate vacuum 33mbar (abs), rated flow 27 ~ 2260m3/h. *Oil type series: oil type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), rated flow 50-2200m3/h. . *Dry claw pump series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), rated flow 60 ~ 1900m3/h.

Category:

sao tome and principeVacuum system engineering

Product Description

Medical vacuum pump negative pressure central suction system

details:

Product Brand:Rietschle

Product model: VC303 Body material: alloy
Drive mode: electric Process use: vacuum Working principle: oil type rotary vane

Motor Power:7.5kW

Ultimate pressure:50Pa

Dimensions:

 

Product number:

MW series: use NASH 2BV2 060/061/070/071, 2BV5 110/111/121/131/161 and 2BE1 202/203 water circulation vacuum pumps
MV series: use Liqile VC50/75/100/150/202/303/400/500/700/900/1100/1300 oil type optional vacuum pump
MC series: use Liqile VLR60/100/150/250/251/300/400/500/1000 dry claw vacuum pump
MG series: use Liqile VTN10, VTN15, VTN25, VTN40 dry rotary vane vacuum pump

Provide international brand medical vacuum pumps, vacuum negative pressure center suction system, professional design, production, installation, first-class quality.

 

 

Working principle (take MW series as an example):

 

Ledun has provided medical center attraction stations for hospitals and medical engineering companies for nearly ten years. Adhering to the design concept of human-oriented science and technology and product excellence, after years of technical accumulation, technological improvement and technological innovation, the products we provide have Three major product advantages of systemization, intelligence, safety and reliability.

 

Systematization:It can provide owners with optimized vacuum pumps, buffer tanks, sewage tanks, sub-cylinders, pipelines, instruments, valves, electrical control cabinets, bacterial filters, pre- and post-filters and other medical central suction station system complete sets of equipment, and also It can provide a complete set of engineering services from product selection, design, manufacturing, to installation, commissioning, and acceptance.

Intelligent:It can provide PLC control module and HMI man-machine interface operation. You can choose to automatically increase or decrease the vacuum pump and alternate operation, reminders for regular replacement of consumables, sound and light alarm for negative pressure exceeding limit, motor operation monitoring, system temperature exceeding alarm, system positive pressure alarm and Intelligent modules such as emergency stop and remote system data transmission make management and operation easier and clearer.

Safe and reliable:In the selection of vacuum pumps, we only use top-notch imported vacuum pumps or high-quality domestic brand-name vacuum pumps to ensure that their design service life reaches more than ten years and meet the strict requirements of hospitals for high reliability of medical equipment; in terms of supporting equipment, Sewage discharge, bacterial filtration, pre- and post-filtration, system monitoring, alarm, emergency stop, remote data transmission and other modules meet the requirements of clean emissions and also ensure that the medical center system can operate safely for a long time.

Features:

*MW series adopts water ring vacuum pump, equipped with steam-water separator, water cycle use, economical and reliable, wide application, ultimate vacuum 33mbar (abs), flow 27-2260m3/h.

*MV series: oil-type rotary vane vacuum pump, special alloy blades, classic direct connection structure, sturdy and durable, ultimate vacuum 0.1mbar (abs), flow 50-2200m3/h.

*MC series: using claw vacuum pump, dry operation, no oil and no water pollution, energy saving and environmental protection, long life, ultimate vacuum 50mbar (abs), flow rate 60 ~ 1900m3/h.

*MG series: It adopts dry rotary vane vacuum pump, dry operation, suitable for anesthesia or breathing exhaust gas discharge, single pump air volume 11.7~42m3/h.

 

typical application:

The MW, MV, and MC series are professionally used for vacuum suction in medical, medical and hospitals, and the MG series are suitable for anesthesia or exhaust gas discharge.

 

Selection and ordering information:

 

NASH MW series selection and ordering information:50Hz,380V,3AC,IP55, F

Attraction station model

Rated
flow

m3/h

limit
pressure

mbar.A

Continuous operating pressure

mbar.A

Vacuum pump
model
Number of vacuum pumps Attraction station control method

Inlet/exhaust port diameter

DN

Vacuum pump speed

r/min

Total power

kW

Average noise

dB(A)

MW060-2

27

33

>80

2BV2060

1+1

Panel

25

2850

1.62

62

MW061-2

52

33

>80

2BV2061

1+1

Panel

25

2850

2.9

65

MW070-2

80

33

>80

2BV2070

1+1

Panel

40

2850

4.7

66

MW071-2

110

33

>80

2BV2071

1+1

Panel

40

2850

7.7

72

MW110-2

165

33

>80

2BV5110

1+1

Panel

50

1450

8.0

63

MW111-2

230

33

>80

2BV5111

1+1

Panel

50

1450

11

68

MW121-2

280

33

>80

2BV5121

1+1

Panel

65

1450

15

69

MW131-2

400

33

>80

2BV5131

1+1

Panel

65

1450

22

73

MW161-2

500

33

>80

2BV5161

1+1

Panel

80

980

30

74

MW202-2

760

33

>80

2BE1202

1+1

Panel

100

980

44

-

MW203-2

1130

33

>80

2BE1203

1+1

Panel

100

980

74

-

MW110-3

330

33

>80

2BV5110

2+1

PLC+HMI

80

1450

8.0

63

MW111-3

460

33

>80

2BV5111

2+1

PLC+HMI

80

1450

11

68

MW121-3

560

33

>80

2BV5121

2+1

PLC+HMI

80

1450

15

69

MW131-3

800

33

>80

2BV5131

2+1

PLC+HMI

80

1450

22

73

MW161-3

1000

33

>80

2BV5161

2+1

PLC+HMI

100

980

45

74

MW202-3

1520

33

>80

2BE1202

2+1

PLC+HMI

125

980

66

-

MW203-3

2260

33

>80

2BE1203

2+1

PLC+HMI

150

980

111

-

Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.

 

Rietschle MV series selection and ordering information:50Hz,380V,3AC,IP55, F

Attraction station model

Rated
flow

m3/h

limit
pressure

mbar.A

Continuous operating pressure

mbar.A

Vacuum pump
model
Number of vacuum pumps Attraction station control method

Inlet/exhaust port diameter

DN

Vacuum pump speed

r/min

Total power

kW

Average noise

dB(A)

MV50-2

50

0.1

>0.5

VC50

1+1

Panel

40

1450

3.0

64

MV75-2

70

0.1

>0.5

VC75

1+1

Panel

40

1450

4.4

64

MV100-2

100

0.1

>0.5

VC100

1+1

Panel

40

1450

6.0

66

MV150-2

150

0.1

>0.5

VC150

1+1

Panel

40

1450

8.0

68

MV202-2

200

0.1

>0.5

VC202

1+1

Panel

50

1450

11

69

MV303-2

300

0.1

>0.5

VC303

1+1

Panel

50

1450

15

70

MV400-2

400

0.1

>0.5

VC400

1+1

Panel

80

950

22

73

MV500-2

550

0.1

>0.5

VC500

1+1

Panel

80

950

30

75

MV700-2

700

0.1

>0.5

VC700

1+1

Panel

80

950

37

78

MV900-2

830

0.1

>0.5

VC900

1+1

Panel

100

950

44

79

MV1100-2

1100

0.1

>0.5

VC1100

1+1

Panel

100

950

60

83

MV202-3

400

0.1

>0.5

VC202

2+1

PLC+HMI

80

1450

16.5

69

MV303-3

600

0.1

>0.5

VC303

2+1

PLC+HMI

80

1450

22.5

70

MV400-3

800

0.1

>0.5

VC400

2+1

PLC+HMI

100

950

33

73

MV500-3

1100

0.1

>0.5

VC500

2+1

PLC+HMI

100

950

45

75

MV700-3

1400

0.1

>0.5

VC700

2+1

PLC+HMI

125

950

55.5

78

MV900-3

1660

0.1

>0.5

VC900

2+1

PLC+HMI

125

950

66

79

MV1100-3

2200

0.1

>0.5

VC1100

2+1

PLC+HMI

150

950

90

83

Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.

 

Rietschle MC series selection and ordering information::50Hz,380V,3AC,IP55, F

Attraction station model

Rated
flow

m3/h

limit
pressure

mbar.A

Continuous operating pressure

mbar.A

Vacuum pump
model
Number of vacuum pumps Attraction station control method

Inlet/exhaust port diameter

DN

Vacuum pump speed

r/min

Total power

kW

Average noise

dB(A)

MC60-2

60

50

>100

VLR60

1+1

Panel

25

2850

2.2

78

MC100-2

100

50

>150

VLR100

1+1

Panel

40

2850

4.4

78

MC150-2

150

50

>100

VLR150

1+1

Panel

40

2850

6.0

79

MC251-2

211

50

>200

VLR251

1+1

Panel

50

2850

8.0

78

MC250-2

235

50

>200

VLR250

1+1

Panel

50

2850

8.0

78

MC300-2

300

50

>200

VLR300

1+1

Panel

50

2850

11

79

MC400-2

385

50

>250

VLR400

1+1

Panel

80

2850

15

82

MC500-2

500

50

>250

VLR500

1+1

Panel

80

2850

18

82

MC1000-2

950

50

>200

VLR1000

1+1

Panel

100

2850

37

82

MC150-3

300

50

>100

VLR251

2+1

PLC+HMI

50

2850

9.0

79

MC251-3

422

50

>200

VLR251

2+1

PLC+HMI

80

2850

12

78

MC250-3

470

50

>200

VLR250

2+1

PLC+HMI

80

2850

12

78

MC300-3

600

50

>200

VLR300

2+1

PLC+HMI

80

2850

16.5

79

MC400-3

770

50

>250

VLR400

2+1

PLC+HMI

100

2850

22.5

82

MC500-3

1000

50

>250

VLR500

2+1

PLC+HMI

100

2850

27

82

MC1000-3

1900

50

>200

VLR1000

2+1

PLC+HMI

150

2850

55.5

82

Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.

 

 

Rietschle MG series selection and ordering information::50Hz,380V,3AC,IP55, F

Attraction station model Number of operating rooms

Rated
flow

m3/h

limit
pressure

mbar.A

Continuous operating pressure

mbar.A

Vacuum pump
model
Number of vacuum pumps Attraction station control method

Inlet/exhaust port diameter

DN

Vacuum pump speed

r/min

Total power

kW

Average noise

dB(A)

MG10-2

≤3

11.7

150

850

VTN10

1+1

PLC+HMI

40

1450

0.74

60

MG15-2

3~7

17.0

150

>150

VTN15

1+1

PLC+HMI

40

1450

1.1

61

MG25-2

7~10

25.8

150

>150

VTN25

1+1

PLC+HMI

40

1450

1.5

64

MG40-2

10~20

42.0

150

850

VTN40

1+1

PLC+HMI

40

1450

3.0

67

Note: The models in the table are for reference for preliminary selection. The specific models need to be optimized for system selection and configuration according to different actual working conditions of the hospital.

 

Detailed information such as product performance curve:

Please call, fax, email or contact our sales engineer via QQ, we will serve you wholeheartedly.

TEL: 020-39987161  E-Mail: lidunjixie@163.com   QQ:121450481